GUIDE TO INSTALLATION AND OPERATION
6 | FLO-1601
Use the keys on the local control panel to step through the displayed menu to configure and adjust
the FLO-1601.
FLO-1601 MENU
STATUS STATUS OK
NO RF INPUT (< -60 dBm)
WEAK RF INPUT (< -55 dBm)
OPTICAL OUT FAIL
RF SIG STRENGTH [-60 dBm, -59 dBm, -58 dBm,….., -1 dBm, 0 dBm] (read-only)
OPTICAL OUT [ON
, OFF]
LNB POWER [OFF
, +13V, +18V]
USER PRESET LOAD [USER 1, USER 2, USER 3, USER 4, USER 5]
SAVE [USER 1, USER 2, USER 3, USER 4, USER 5]
CONFIG ALARMS NO RF INPUT ALARM LEVEL [GREEN, YELLOW, RED, FLASH RED]
ALARM REPORT [NONE, GPI]
WEAK RF INPUT ALARM LEVEL [GREEN, YELLOW, RED, FLASH RED]
ALARM REPORT [NONE, GPI]
OPTICAL OUT FAIL ALARM LEVEL [GREEN, YELLOW, RED, FLASH RED]
ALARM REPORT [NONE, GPI]
VERSION FLO-1601:xxx
FACTORY DEFAULT [RESTORE]
Notes on the menu items:
OPTICAL OUT – turn the laser ON or OFF
LNB POWER – Turn the power sent to the LNB (Low Noise Block Converter) via the RF input connector
OFF, or select the LNB voltage as +13V or +18V.
USER PRESET – the FLO-1601 has 5 registers that can store full configuration data. Use the LOAD and
SAVE menu items to select a register (USER 1 to USER 5) and either save the current configuration into that
register (SAVE) or reconfigure the FLO-1601 according to the contents of the register (LOAD).
CONFIG ALARMS / ALARM LEVEL – for each alarm, set the color that will be displayed on the FLO-1601’s
status LED.
CONFIG ALARMS/ ALARM REPORT – for each alarm, select whether that alarm will be reported on the
Densité frame’s GPI output. See the manual for the frame’s controller card for more information about this
feature.